UFM Vortex Polysulphone


UFM CPM Series Description
This flowmeter is for monitoring water flow such as water add on concrete trucks.
It operates in batch (total) mode or rate for continuous mix.
• No moving parts to hang up
• 11/2% accuracy
• Not destroyed by compressed air
• 3 digit display optional
Electrical Specifications
• Input Power: 10 – 30 VDC @ 80 mA
• Electrical Connection = Weatherproof Pin Connector (standard)
Material Specifications
Flow bodies of brass or Polysulfone with PVDF sensors and Viton® seals standard.
User-Configurable Options
• Engineering units (GPM, LPM)
Instrument Specifi cations
• Max flow 50 GPM
• Flow Accuracy: ±1.5% of indicated total, 1.5% Full Scale for rate, Turndown: 10:1
• Operating Pressure 200 PSI (13.6 bar) Polysulphone, 300 PSIG (20 Bar) Brass
• General Response time: 450 ms
Fluid temperature limits: 35-150°F (2-66°C) continuous use.
Enclosure rating: IP 65, Type 1, 3, 4, 12 and 13
• Pipe Connections: 1 inch NPT female
• Pulse or 4-20 mA rate output
• Mounting lugs integral to body
• Back pressure of 10 PSIG required

Download or View Below Product Literature :

1. CoolPoint Flowmeter for Continuous or Batch Water Add on Concrete Trucks